{"id":1574,"date":"2022-11-25T20:11:29","date_gmt":"2022-11-25T20:11:29","guid":{"rendered":"https:\/\/www.lunit.io\/publication\/artificial-intelligence-assistance-for-women-who-had-spot-compression-view-reducing-recall-rates-for-digital-mammography\/"},"modified":"2025-11-02T03:10:56","modified_gmt":"2025-11-02T03:10:56","slug":"artificial-intelligence-assistance-for-women-who-had-spot-compression-view-reducing-recall-rates-for-digital-mammography","status":"publish","type":"publication","link":"https:\/\/www.lunit.io\/en\/publication\/artificial-intelligence-assistance-for-women-who-had-spot-compression-view-reducing-recall-rates-for-digital-mammography\/","title":{"rendered":"Artificial intelligence assistance for women who had spot compression view: reducing recall rates for digital mammography"},"content":{"rendered":"<h3>Artificial intelligence assistance for women who had spot compression view: reducing recall rates for digital mammography<\/h3>\n<p>Si Eun Lee, Ga Ram Kim, et al.<\/p>\n<p><strong>Acta Radiologica, 2022<\/strong><\/p>\n<p><strong>Abstract<\/strong><br \/>\n<strong>Background<\/strong><br \/>\nMammography yields inevitable recall for indeterminate findings that need to be confirmed with additional views.<\/p>\n<p><strong>Purpose<\/strong><br \/>\nTo explore whether the artificial intelligence (AI) algorithm for mammography can reduce false-positive recall in patients who undergo the spot compression view.<br \/>\nMaterial and Methods<br \/>\nFrom January to December 2017, 236 breasts from 225 women who underwent the spot compression view due to focal asymmetry, mass, or architectural distortion on standard digital mammography were included. Three readers who were blinded to the study purpose, patient information, previous mammograms, following spot compression views, and any clinical or pathologic reports retrospectively reviewed 236 standard mammograms and determined the necessity of patient recall and the probability of malignancy per breast, first without and then with AI assistance. The performances of AI and the readers were evaluated with the recall rate, area under the receiver operating characteristic curve (AUC), sensitivity, specificity, and accuracy.<\/p>\n<p><strong>Results<\/strong><br \/>\nAmong 236 examinations, 8 (3.4%) were cancers and 228 (96.6%) were benign. The recall rates of all three readers significantly decreased with AI assistance (P\u2009&lt;\u20090.05). The reader-averaged recall rates significantly decreased with AI assistance regardless of breast composition (fatty breasts: 32.7% to 24.1%m P\u2009=\u20090.002; dense breasts: 33.6% to 21.2%, P\u2009&lt;\u20090.001). The reader-averaged AUC increased with AI assistance and was comparable to that of standalone AI (0.835 vs. 0.895; P\u2009=\u20090.234). The reader-averaged specificity (71.2% to 79.8%, P\u2009&lt;\u20090.001) and accuracy (71.3% to 79.7%, P\u2009&lt;\u20090.001) significantly improved with AI assistance.<\/p>\n<p><strong>Conclusion<\/strong><br \/>\nAI assistance significantly reduced false-positive recall without compromising cancer detection in women with focal asymmetry, mass, or architectural distortion on standard digital mammography regardless of mammographic breast density.<\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/journals.sagepub.com\/doi\/10.1177\/02841851221140556\"><strong>Read the full paper<\/strong><\/a><\/p>\n","protected":false},"featured_media":0,"template":"","publication-oncology":[],"publication-region":[87],"publication-type":[],"radiology":[97,98,96],"class_list":["post-1574","publication","type-publication","status-publish","hentry","publication-region-asia","radiology-breast","radiology-enhancing-workflow-efficiency","radiology-lunit-insight"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Artificial intelligence assistance for women who had spot compression view: reducing recall rates for digital mammography - Lunit<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.lunit.io\/en\/publication\/artificial-intelligence-assistance-for-women-who-had-spot-compression-view-reducing-recall-rates-for-digital-mammography\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Artificial intelligence assistance for women who had spot compression view: reducing recall rates for digital mammography - Lunit\" \/>\n<meta property=\"og:description\" content=\"Artificial intelligence assistance for women who had spot compression view: reducing recall rates for digital mammography Si Eun Lee, Ga Ram Kim, et al. Acta Radiologica, 2022 Abstract Background Mammography yields inevitable recall for indeterminate findings that need to be confirmed with additional views. Purpose To explore whether the artificial intelligence (AI) algorithm for mammography [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.lunit.io\/en\/publication\/artificial-intelligence-assistance-for-women-who-had-spot-compression-view-reducing-recall-rates-for-digital-mammography\/\" \/>\n<meta property=\"og:site_name\" content=\"Lunit\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-02T03:10:56+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@lunit_ai\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.lunit.io\\\/en\\\/publication\\\/artificial-intelligence-assistance-for-women-who-had-spot-compression-view-reducing-recall-rates-for-digital-mammography\\\/\",\"url\":\"https:\\\/\\\/www.lunit.io\\\/en\\\/publication\\\/artificial-intelligence-assistance-for-women-who-had-spot-compression-view-reducing-recall-rates-for-digital-mammography\\\/\",\"name\":\"Artificial intelligence assistance for women who had spot compression view: reducing recall rates for digital mammography - Lunit\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.lunit.io\\\/en\\\/#website\"},\"datePublished\":\"2022-11-25T20:11:29+00:00\",\"dateModified\":\"2025-11-02T03:10:56+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.lunit.io\\\/en\\\/publication\\\/artificial-intelligence-assistance-for-women-who-had-spot-compression-view-reducing-recall-rates-for-digital-mammography\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.lunit.io\\\/en\\\/publication\\\/artificial-intelligence-assistance-for-women-who-had-spot-compression-view-reducing-recall-rates-for-digital-mammography\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.lunit.io\\\/en\\\/publication\\\/artificial-intelligence-assistance-for-women-who-had-spot-compression-view-reducing-recall-rates-for-digital-mammography\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.lunit.io\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Artificial intelligence assistance for women who had spot compression view: reducing recall rates for digital mammography\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.lunit.io\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.lunit.io\\\/en\\\/\",\"name\":\"Lunit\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.lunit.io\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.lunit.io\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.lunit.io\\\/en\\\/#organization\",\"name\":\"Lunit\",\"url\":\"https:\\\/\\\/www.lunit.io\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.lunit.io\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.lunit.io\\\/en\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/Logo-black.svg\",\"contentUrl\":\"https:\\\/\\\/www.lunit.io\\\/en\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/Logo-black.svg\",\"width\":189,\"height\":52,\"caption\":\"Lunit\"},\"image\":{\"@id\":\"https:\\\/\\\/www.lunit.io\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/lunit_ai\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/lunit-inc\",\"https:\\\/\\\/x.com\\\/lunitoncology\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Artificial intelligence assistance for women who had spot compression view: reducing recall rates for digital mammography - Lunit","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.lunit.io\/en\/publication\/artificial-intelligence-assistance-for-women-who-had-spot-compression-view-reducing-recall-rates-for-digital-mammography\/","og_locale":"en_US","og_type":"article","og_title":"Artificial intelligence assistance for women who had spot compression view: reducing recall rates for digital mammography - Lunit","og_description":"Artificial intelligence assistance for women who had spot compression view: reducing recall rates for digital mammography Si Eun Lee, Ga Ram Kim, et al. Acta Radiologica, 2022 Abstract Background Mammography yields inevitable recall for indeterminate findings that need to be confirmed with additional views. Purpose To explore whether the artificial intelligence (AI) algorithm for mammography [&hellip;]","og_url":"https:\/\/www.lunit.io\/en\/publication\/artificial-intelligence-assistance-for-women-who-had-spot-compression-view-reducing-recall-rates-for-digital-mammography\/","og_site_name":"Lunit","article_modified_time":"2025-11-02T03:10:56+00:00","twitter_card":"summary_large_image","twitter_site":"@lunit_ai","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.lunit.io\/en\/publication\/artificial-intelligence-assistance-for-women-who-had-spot-compression-view-reducing-recall-rates-for-digital-mammography\/","url":"https:\/\/www.lunit.io\/en\/publication\/artificial-intelligence-assistance-for-women-who-had-spot-compression-view-reducing-recall-rates-for-digital-mammography\/","name":"Artificial intelligence assistance for women who had spot compression view: reducing recall rates for digital mammography - Lunit","isPartOf":{"@id":"https:\/\/www.lunit.io\/en\/#website"},"datePublished":"2022-11-25T20:11:29+00:00","dateModified":"2025-11-02T03:10:56+00:00","breadcrumb":{"@id":"https:\/\/www.lunit.io\/en\/publication\/artificial-intelligence-assistance-for-women-who-had-spot-compression-view-reducing-recall-rates-for-digital-mammography\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.lunit.io\/en\/publication\/artificial-intelligence-assistance-for-women-who-had-spot-compression-view-reducing-recall-rates-for-digital-mammography\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.lunit.io\/en\/publication\/artificial-intelligence-assistance-for-women-who-had-spot-compression-view-reducing-recall-rates-for-digital-mammography\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.lunit.io\/en\/"},{"@type":"ListItem","position":2,"name":"Artificial intelligence assistance for women who had spot compression view: reducing recall rates for digital mammography"}]},{"@type":"WebSite","@id":"https:\/\/www.lunit.io\/en\/#website","url":"https:\/\/www.lunit.io\/en\/","name":"Lunit","description":"","publisher":{"@id":"https:\/\/www.lunit.io\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.lunit.io\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.lunit.io\/en\/#organization","name":"Lunit","url":"https:\/\/www.lunit.io\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.lunit.io\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.lunit.io\/en\/wp-content\/uploads\/2025\/10\/Logo-black.svg","contentUrl":"https:\/\/www.lunit.io\/en\/wp-content\/uploads\/2025\/10\/Logo-black.svg","width":189,"height":52,"caption":"Lunit"},"image":{"@id":"https:\/\/www.lunit.io\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/x.com\/lunit_ai","https:\/\/www.linkedin.com\/company\/lunit-inc","https:\/\/x.com\/lunitoncology"]}]}},"_links":{"self":[{"href":"https:\/\/www.lunit.io\/en\/wp-json\/wp\/v2\/publication\/1574","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.lunit.io\/en\/wp-json\/wp\/v2\/publication"}],"about":[{"href":"https:\/\/www.lunit.io\/en\/wp-json\/wp\/v2\/types\/publication"}],"wp:attachment":[{"href":"https:\/\/www.lunit.io\/en\/wp-json\/wp\/v2\/media?parent=1574"}],"wp:term":[{"taxonomy":"publication-oncology","embeddable":true,"href":"https:\/\/www.lunit.io\/en\/wp-json\/wp\/v2\/publication-oncology?post=1574"},{"taxonomy":"publication-region","embeddable":true,"href":"https:\/\/www.lunit.io\/en\/wp-json\/wp\/v2\/publication-region?post=1574"},{"taxonomy":"publication-type","embeddable":true,"href":"https:\/\/www.lunit.io\/en\/wp-json\/wp\/v2\/publication-type?post=1574"},{"taxonomy":"radiology","embeddable":true,"href":"https:\/\/www.lunit.io\/en\/wp-json\/wp\/v2\/radiology?post=1574"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}