Artificial Intelligence for Assessment of Endotracheal Tube Position on Chest Radiographs: Validation in Patients From Two Institutions

Published 2023

Artificial Intelligence for Assessment of Endotracheal Tube Position on Chest Radiographs: Validation in Patients From Two Institutions

Ji Yeong An, Eui Jin Hwang, Gunhee Nam, et al.

American Journal of Roentgenology, 2023

Abstract
BACKGROUND. Timely and accurate interpretation of chest radiographs obtained to evaluate endotracheal tube (ETT) position is important for facilitating prompt adjustment if needed.

OBJECTIVE. The purpose of our study was to evaluate the performance of a deep learning (DL)-based artificial intelligence (AI) system for detecting ETT presence and position on chest radiographs in three patient samples from two different institutions.

METHODS. This retrospective study included 539 chest radiographs obtained im-mediately after ETT insertion from January 1 to March 31, 2020, in 505 patients (293men, 212 women; mean age, 63 years) from institution A (sample A); 637 chest radio-graphs obtained from January 1 to January 3, 2020, in 302 patients (157 men, 145 wom-en; mean age, 66 years) in the ICU (with or without an ETT) from institution A (sample B); and 546 chest radiographs obtained from January 1 to January 20, 2020, in 83 patients(54 men, 29 women; mean age, 70 years) in the ICU (with or without an ETT) from institu-tion B (sample C). A commercial DL-based AI system was used to identify ETT presence and measure ETT tip-to-carina distance (TCD). The reference standard for proper ETT position was TCD between greater than 3 cm and less than 7 cm, determined by human readers. Critical ETT position was separately defined as ETT tip below the carina or TCD of 1 cm or less. ROC analysis was performed.

RESULTS. AI had sensitivity and specificity for identification of ETT presence of100.0% and 98.7% (sample B) and 99.2% and 94.5% (sample C). AI had sensitivity and specificity for identification of improper ETT position of 72.5% and 92.0% (sample A),78.9% and 100.0% (sample B), and 83.7% and 99.1% (sample C). At a threshold y-axis TCDof 2 cm or less, AI had sensitivity and specificity for critical ETT position of 100.0% and96.7% (sample A), 100.0% and 100.0% (sample B), and 100.0% and 99.2% (sample C).

CONCLUSION. AI identified improperly positioned ETTs on chest radiographs obtained after ETT insertion as well as on chest radiographs obtained of patients in the ICU at two institutions.

CLINICAL IMPACT. Automated AI identification of improper ETT position on chest radiographs may allow earlier repositioning and thereby reduce complications.